Let's cut straight to it: 29 CFR Part 1915, Subpart I governs personal protective equipment (PPE) in shipyard employment. That's welding on hulls, sandblasting decks, and handling hazardous materials amid saltwater corrosion. Public utilities? Think high-voltage substations, underground vaults, or wind turbine maintenance. These operations fall squarely under OSHA's General Industry standards in 29 CFR 1910, not maritime shipyard rules.

Scope of 1915 Subpart I: Shipyards Only

OSHA's 1915 is laser-focused on shipyards—defined as facilities repairing, building, or breaking vessels. Section 1915.1 explicitly limits its reach to "shipyard employment," excluding general industry like utilities. If your team at a power plant or water treatment facility isn't clambering over a dry-docked freighter, this subpart doesn't touch you.

I've seen confusion arise during utility projects near ports, where crews might assist with vessel tie-ups. Even then, OSHA clarifies in interpretive letters (check CPL 02-01-049) that utility workers remain under 1910 unless fully integrated into shipyard ops. Bottom line: no ship, no 1915 applicability.

Key Differences: Why Utility PPE Needs Go Beyond Shipyard Specs

1915 Subpart I mandates PPE like eye protection for flying particles (1915.84) and respirators for toxic fumes from ship coatings. Solid for maritime grit, but public utilities face arc flash blasts reaching 40 cal/cm², per NFPA 70E and OSHA 1910.269. Shipyard PPE selection under 1915.152 emphasizes hazard assessments for welding and grinding—critical, yet it skimps on electrical specifics.

  • Electrical Hazards: Utilities demand ASTM F1506 arc-rated clothing; 1915 doesn't address voltage-rated gloves or insulated tools per 1910.137.
  • Falls and Heights: Turbine or pole work requires 1910.140 personal fall arrest systems tailored to dynamic loads, beyond shipyard scaffolding in 1915.74.
  • Chemical and Confined Spaces: Utility vaults expose workers to hydrogen sulfide or chlorine—1910.146 permit-required spaces demand more robust PPE ensembles than 1915's painting ops.

These gaps aren't oversights; they're scope-driven. Shipyards prioritize vessel-specific perils like immersion risks (1915.158 life rings), irrelevant to a substation crew dodging live lines.

Practical Shortfalls in Real-World Utility Scenarios

Picture a California utility crew retrofitting solar farms—heat stress hits 110°F, dust storms rage, and panels spark under fault. 1915 Subpart I's cooling vests (1915.153) help, but fall short without 1910.132's full hazard assessment integrating UV exposure and ergonomic strain. We've audited sites where teams defaulted to "generic PPE," leading to incidents OSHA could trace to mismatched standards.

Another shortfall: training. 1915.81 requires shipyard PPE donning demos, but utilities need 1910.269 Appendix E for live-line work protocols. Research from NIOSH (Publication No. 2004-101) shows utility electrocutions drop 30% with standard-specific training—1915 alone won't cut it.

Navigating Compliance: Stick to 1910.132 and Utility Add-Ons

Always start with a site-specific hazard analysis under 1910.132(d). Layer in 1910.269 for electric power generation, transmission, and distribution—it's the gold standard for utilities. For deeper dives, OSHA's eTool on Electrical Power Generation offers free checklists.

Pro tip: Cross-reference with ANSI Z87.1 for eye/face protection; it's harmonized across standards but customized via utility JHA. Individual results vary by site conditions, so document everything—OSHA loves paper trails.

In short, 1915 Subpart I shines in shipyards but stays docked there. For public utilities, lean on 1910's broader toolkit to keep your crews safe and compliant.