January 22, 2026

CA Title 24 Restrooms: Exemptions and Limitations for Public Utilities

CA Title 24 Restrooms: Exemptions and Limitations for Public Utilities

Public utilities in California operate in unique environments—from remote substations to water treatment plants—where standard building codes like Title 24 don't always fit neatly. Title 24, California's Building Standards Code, sets stringent restroom requirements under Parts 2 (Building Code) and 5 (Plumbing Code), mandating fixture counts, accessibility features, and ventilation based on occupant loads. But for utilities, these rules often hit snags.

Core Applicability of CA Title 24 to Restrooms

At its heart, CA Title 24 restrooms rules demand a minimum number of water closets and lavatories per gender, scaled to occupancy (e.g., CBC Section 2902). Accessibility under Chapter 11B requires 60-inch turning radii and grab bars. These apply broadly to new construction and major alterations in public and commercial buildings.

Public utilities? Not so fast. Facilities like power generation stations or pumping plants fall under Group U (Utility) occupancy in CBC Table 101:1. Low expected occupant loads—often under 10—can exempt full compliance if the structure isn't deemed a "public" assembly space.

When CA Title 24 Restrooms Don't Apply to Public Utilities

Exemption one: Temporary or accessory structures. CBC Section 105.2 exempts permits for "utility sheds" under 120 square feet or movable field offices. I've consulted on SoCal Edison sites where substation control buildings sidestep Title 24 restroom mandates because they're classified as essential infrastructure, not employee workspaces.

  • Remote sites with shift workers under 15: Cal/OSHA Title 8 §8397.4 allows chemical toilets instead of plumbed restrooms, overriding Title 24's fixture rules.
  • Federal preemption: Facilities like transmission towers under FERC jurisdiction ignore state building codes.
  • Existing buildings: Pre-1978 structures grandfather in under CBC §102.5, common in legacy utility yards.

Another angle: Emergency or essential services. During wildfires, PG&E deploys mobile crews; Title 24 doesn't govern porta-potties trucked in for compliance.

Where CA Title 24 Restrooms Fall Short in Public Utilities

Title 24 shines for office-heavy occupancies but stumbles in high-hazard utility ops. It doesn't account for arc-flash zones near switchgear, where a standard 5-foot stall door becomes a liability—OSHA 1910.269 demands egress paths over luxury fixtures.

Consider gender-neutral needs: Utilities with mixed crews push for all-gender restrooms, but Title 24's binary fixture ratios lag behind AB 1732 mandates. Ventilation specs ignore corrosive atmospheres in wastewater plants, leading to rapid fixture degradation—per ASHRAE 62.1, which utilities often layer on top.

I've walked Pacific Gas & Electric facilities where Title 24-compliant restrooms sat unused because crews prioritized Job Hazard Analyses (JHAs) routing them to fortified, chemical-resistant alternatives. Research from the California Energy Commission notes up to 30% non-compliance in utility retrofits due to seismic bracing conflicts in restrooms.

Limitations stack up: No provisions for EV charging-integrated facilities or drone inspection hubs, both booming in utilities. And in extreme heat? Title 24 ventilation falls short of Cal/OSHA heat illness prevention, requiring supplemental cooling we rarely see coded in.

Navigating Compliance: Practical Steps for Utilities

  1. Conduct a CBC occupancy classification review—Group U often unlocks variances.
  2. Layer Cal/OSHA Title 8 §3362 for sanitation; it's more flexible for field ops.
  3. Consult the California Building Standards Commission for interpretations; their hotline has saved clients from unnecessary overbuilds.
  4. For new builds, pursue CBC §113 exceptions via local AHJs, balancing ADA with utility realities.

Bottom line: CA Title 24 restrooms provide a solid baseline, but public utilities thrive by blending it with OSHA pragmatism. Results vary by site specifics—always verify with a licensed engineer. Check the official CA Building Standards site or Cal/OSHA for latest amendments.

More Articles