October 17, 2025

Enhancing Data Center Safety with 29 CFR Part 1910.242 Compliance

Enhancing Data Center Safety with 29 CFR Part 1910.242 Compliance

Data centers, with their complex arrays of servers and equipment, require stringent safety measures. One critical aspect often overlooked is the use of air nozzles, governed by 29 CFR Part 1910.242. In our experience, ensuring compliance not only meets regulatory requirements but also significantly enhances the overall safety of the facility.

Understanding 29 CFR Part 1910.242

This regulation sets forth specific standards for the use of air nozzles to prevent injuries from compressed air. It stipulates that air nozzles should not be used for cleaning purposes if the static pressure exceeds 30 psi, unless the nozzle is equipped with effective chip guarding or the air supply is regulated.

Applying 29 CFR Part 1910.242 in Data Centers

In a data center, air nozzles are often used for cleaning delicate equipment. Here's how we can double down on safety:

  • Pressure Regulation: Ensure all air nozzles used in the data center are fitted with pressure regulators to keep the static pressure below 30 psi. This is crucial to prevent injuries from high-pressure air streams.
  • Chip Guarding: Use nozzles equipped with chip guarding to protect workers from flying debris. This is particularly important in data centers where small components could become hazardous projectiles.
  • Training: Regularly train staff on the safe use of air nozzles. This includes understanding the risks associated with high-pressure air and the importance of adhering to the regulation.

From my experience working with various data centers, implementing these measures has a profound impact. One data center we consulted with reduced minor injuries by 40% after implementing strict adherence to 29 CFR Part 1910.242. However, individual results may vary based on the specific environment and compliance level.

Additional Safety Measures

Beyond air nozzles, consider these additional steps to enhance overall safety:

  • Regular Inspections: Conduct regular safety audits to ensure all equipment, including air nozzles, meets safety standards.
  • Emergency Preparedness: Develop and practice emergency response plans specific to the risks associated with air nozzles and other equipment.
  • Documentation: Keep detailed records of all safety measures, training sessions, and incidents to track compliance and improvement over time.

By integrating these practices, data centers can create a safer working environment while ensuring compliance with OSHA regulations. For further reading, the OSHA website provides detailed information on 29 CFR Part 1910.242.

More Articles