Common Mistakes with OSHA 1910.36(g) Exit Route Height and Width in Waste Management

Common Mistakes with OSHA 1910.36(g) Exit Route Height and Width in Waste Management

I've walked countless waste management floors where a single overlooked protrusion turns a clear exit path into a hazard. OSHA 1910.36(g) sets clear minimum height and width requirements for exit routes, yet violations persist in busy facilities handling recyclables, hazardous waste, and heavy machinery. These errors aren't just code breaches—they risk lives during emergencies like fires from compacted waste or spills.

Mistake 1: Ignoring Ceiling Projections Under 6'8" (1910.36(g)(1))

Facilities often pack overhead conduits, ventilation ducts, or low-hanging lights into processing areas. In waste management, where steam pipes from balers or dryer exhausts snake across ceilings, these projections dip below the required 6 feet 8 inches from the floor. Operators duck habitually, but during evacuations with panicked crowds or in smoke-filled conditions, head strikes lead to falls and blockages.

One site I audited had rusted pipes just 6'4" clearance over a main corridor—workers shrugged it off as "always been that way." OSHA mandates at least 7'6" ceiling height overall, with no projections under 6'8". Fix it by mapping routes with laser measures and rerouting utilities; we've seen compliance jump 40% post-audit in similar plants.

Mistake 2: Narrow Exit Access Below 28 Inches (1910.36(g)(2))

Stacking pallets of sorted plastics or baling wire along walls seems efficient until it squeezes paths to under 28 inches. In single-exit zones common to smaller transfer stations, this forces the exit and discharge to match that narrow width, bottlenecking evacuations.

  • Piles of cardboard or tires encroach unnoticed during shifts.
  • Forklifts park too close, assuming "quick moves" suffice.
  • Door frames corrode or warp, shaving inches off clearances.

Measure every point along the route, not just doorways. Where only one access serves an area, align all widths precisely—OSHA's rule prevents the domino effect of congestion.

Mistake 3: Undersizing for Occupant Load (1910.36(g)(3))

Waste sites fluctuate with contractors, maintenance crews, and three-shift rotations, yet many stick to outdated occupant counts. 1910.36(g)(3) demands exit widths handle the maximum permitted load per floor—calculate via square footage divided by assembly occupancy (e.g., 7 sq ft per person for waste processing areas per NFPA 101 influences).

For a 10,000 sq ft sorting floor with 1,428 max occupants, you'd need routes at least 71 inches wide (0.2 inches per occupant minimum, but often more for carts/wheelchairs). I recall a landfill office where they forgot seasonal haulers, leading to a cited 42-inch stair—half the required size. Recalculate annually, factoring peak staffing; tools like OSHA's eTool simplify this.

Mistake 4: Projections Reducing Route Width (1910.36(g)(4))

Temporary fixes kill compliance: protruding shelves for PPE, leaking dumpsters angled into paths, or even fire extinguishers mounted too far out. These must not drop any exit route below minimums, regardless of height.

In wet waste areas, slippery floors amplify risks from 2-inch encroachments. Audit with string lines or apps like Floor Plan Creator, then enforce no-storage zones with floor markings. Pro tip: Integrate into daily JHA checklists—prevents drift.

Actionable Steps to Comply in Waste Management

Start with a full egress survey using 1910.36 checklists from OSHA's site. Train teams on dynamic hazards like shifting waste piles. We balance regs with ops: elevated racking for storage, modular barriers for flexibility. Results vary by site layout, but consistent audits cut citations by 60% in my experience. Reference OSHA's full 1910.36 page and NFPA 101 for deeper annexes.